Item No.: 00220
Rechargeable 3.0V CR2 / IFR15270 3.2V LiFePO4 Battery For Medical Equipment Feature: 1. The model name:IFR15270/RCR2 3.2V 200mAh 2. 3.2V IFR15270/CR2 200mAh LiFePO4 battery can replace 3.0V CR2 non-rechargeable Lithium battery
Description
Description

Rechargeable 3.0V CR2 LiFePO4 Battery For Medical Equipment

Rechargeable 3.0V CR2 / IFR15270 3.2V LiFePO4 Battery For Medical Equipment

 

 Feature for Rechargeable 3.0V CR2 LiFePO4 Battery For Medical Equipment

 

1. The model name:IFR15270/RCR2 3.2V 200mAh

2. 3.2V IFR15270/CR2 200mAh LiFePO4 battery  can replace 3.0V CR2 non-rechargeable Lithium battery

3. There is a  ong cycle life,it is about 2000 times

4. The application is widely,for digital camera,ACP pen and so on.

5. High energy density,High open circuit voltage

6. Wide range of operating temperature,Stable operating voltage and current

7. Low self-discharge rate (less than 2% per year at 20°C).

 

 

Specification for Rechargeable 3.0V CR2 LiFePO4 Battery For Medical Equipment

 

Rechargeable 3.0V CR2/IFR15270 3.2V LiFePO4 Battery for Medical Equipment/ACP pen

No.

Item

General Parameter

Remark

1

Rated Capacity

Typical

200mAh

Standard discharge(0.2 C5A) after Standard charge

Minimum

190mAh

2

Nominal Voltage

3.2V

Mean Operation Voltage

3

Voltage at end of

Discharge

2.0V

Discharge Cut-off Voltage

4

Charging Voltage

3.65V

 

5

Internal Impedance

≤150mΩ

Internal resistance measured at AC 1KHafter 50% charge

The measure must uses the new batteries that within one week after shipment and cycles less than 5 times

6

Standard charge

Constant Current 0.2C5A

Constant Voltage 3.65V

0.01 C5A cut-off

 

7

Standard discharge

Constant current 0.2 C5A

end voltage 2.0V

 

8

Fast charge

Constant Current 1C5A

Constant Voltage 3.65V

0.01 C5A cut-off

 

9

Fast discharge

Constant current 1 C5A

end voltage 2.0V

 

10

Maximum Continuous Charge Current

1 C5A

 

11

Maximum Continuous Discharge Current

1.5C5A

 

12

Operation Temperature Range

Charge: 0~45℃

60±25%R.H.

Bare Cell

Discharge: -10~60℃

13

Storage Temperature Range

Less than 1 year: -20~25℃

60±25%R.H.

at the shipment state

less than 3 months: -20~40℃

Less than 7 day : -20~65℃

14

Cell  Dimension

 

High: 27.0±0.5 mm

Initial  Dimension

Diameter:15.0±0.5 mm

 
 
 
 

Main Applications for Rechargeable 3.0V CR2 LiFePO4 Battery For Medical Equipment

 

1. Utility meter (water, electricity, gas meter, AMR)

2. Alarm or security equipment (smoke alarm system, detector)

3. GPS tracking

4. Teal time clock

5. Digital control machine

6. Military

7. Remote monitoring systems

8. Car electronics

9. Camera

 

 

Picture &Drawing:

 

Rechargeable 3.0V CR2/IFR15270 3.2V LiFePO4 Battery for Medical Equipment/ACP pen

 

Cautions in use

To ensure proper use of the battery please read the manual carefully before using it.

   . Handling

  •  Do not expose to, dispose of the battery in fire.
  • Do not put the battery in a charger or equipment with wrong terminals connected.
  • Avoid shorting the battery
  • Avoid excessive physical shock or vibration.
  • Do not disassemble or deform the battery.
  • Do not immerse in water.
  • Do not use the battery mixed with other different make, type, or model batteries.
  • Keep out of the reach of children.

     . Storage

  • Store the battery in a cool, dry and well-ventilated area.

     . Disposal

  • Regulations vary for different countries. 
  • Dispose of in accordance with local regulations.

 

 

Battery operation instruction

 

Discharging current

The discharging current does not have to surpass this specification book stipulation the biggest discharging current, the over sized electric current electric discharge can cause the battery capacity play to reduce and to cause the battery heat.

 

Electric discharge temperature 

The battery discharge must carry on in the ambient temperature scope which this specification book stipulated.

 

Storing the Batteries

The battery should store in the product specification book stipulation temperature range. If has surpasses above for six months the long time storage, the discharge capacity will decrease sharply.

 

Period of Warranty

 

Because batteries utilize a chemical reaction, battery performance will deteriorate over time even if stored for a long period of time without being used. In addition, if the various usage conditions such as discharge, ambient temperature, are not maintained within the specified ranges the life expectancy of the battery may be shortened or the device in which the battery is used may be damaged by electrolyte leakage. Please change the battery in time.